This article will explain how to calibrate the AUTOMATiQ, using the integrated FIT System.
When to conduct a calibration
Calibrating the automatic shifting interface is always needed after one of the following:
- After the initial assembly of the e-bike.
- When the automatic shifting hub interface (e.g. AUTOMATiQ) was removed for maintenance reasons.
- When the system does not work properly.
Calibration options
These are the many ways you can calibrate an AUTOMATiQ hub interface:
With a smartphone or tablet
With a CLiQ controller
With the bike's integrated system
- How to calibrate the AUTOMATiQ using a BOSCH integrated display
- How to calibrate the AUTOMATiQ using the Bafang integrated display
- How to calibrate the AUTOMATiQ using the FIT integrated display
- How to calibrate the AUTOMATiQ using the Specialized integrated display
Step-by-step instructions
Video
Tools
- A bicycle with a FIT integrated system.
Calibration instructions
- Turn on the e-bike with the FIT system.
- Enter the setup menu using the joystick.
- Select "Calibration" and confirm by pressing the joystick.
- Select "Calibrate enviolo" and confirm by pressing the joystick.
- Lift up the rear wheel and pedal fast and easy.
- Start calibration by pressing the joystick again.
-
Pedal the e-bike lightly through the entire calibration process (preferably on a stand with the rear wheel off the ground), while the system shifts from full underdrive to full overdrive multiple times and completes the calibration process.
- This process will take ~25 seconds.
Calibration done
Enjoy the ride! If you followed all the steps the e-bike is ready to go. If you have any questions, please reach out to our Support team.