This article will explain how to calibrate the AUTOMATiQ, using the integrated BOSCH System.
When to conduct a calibration
Calibrating the automatic shifting interface is always needed after one of the following:
- After the initial assembly of the e-bike.
- When the automatic shifting hub interface (e.g. AUTOMATiQ) was removed for maintenance reasons.
- When the system does not work properly.
Calibration options
These are the many ways you can calibrate an AUTOMATiQ hub interface:
With a smartphone or tablet
With a CLiQ controller
With the bike's integrated system
- How to calibrate the AUTOMATiQ using a BOSCH integrated display
- How to calibrate the AUTOMATiQ using the Bafang integrated display
- How to calibrate the AUTOMATiQ using the FIT integrated display
- How to calibrate the AUTOMATiQ using the Specialized integrated display
Step-by-step instructions
BOSCH Intuvia
Video
Tools
-
A bicycle with a BOSCH Intuvia integrated system.
Calibration instructions
- Turn on the Bosch Intuvia system.
- Select no motor assist.
-
Activate the "configuration mode" through simultaneous push and hold of [RESET] and [i] buttons (A & B).
- Push the [i] button (B), until you can see "gear calibration" on the screen.
- While pedaling, press the "Light" button (C) to start calibration.
-
Pedal the e-bike lightly through the entire calibration process (preferably on a stand with the rear wheel off the ground), while the system shifts from full underdrive to full overdrive multiple times and completes the calibration process.
- This process can take ~25 seconds.
- After completion of the calibration process, the system returns to the ride mode automatically.
BOSCH Nyon 2
Video
Tools
- A bicycle with a BOSCH Nyon 2 integrated system.
Calibration instructions
- Turn on the Bosch Nyon system.
- Select no motor assist.
- Enter the "Settings" menu by pressing the [>] and [<] keys and confirm your selection with the pound key [<>].
- Use [+] and [-] to select the menu item "My eBike" and confirm your selection with [<>] or [>].
- Select the menu item "eShift" and confirm your selection.
- Select the menu item "Calibration" and confirm your selection.
-
Pedal the e-bike lightly through the entire calibration process (preferably on a stand with the rear wheel off the ground), while the system shifts from full underdrive to full overdrive multiple times and completes the calibration process.
- This process can take ~25 seconds.
- After completion of the calibration process exit the menu.
BOSCH Kiox
Video
Tools
-
A bicycle with a BOSCH Kiox integrated system.
Calibration instructions
- Turn on the Bosch Kiox system.
- Select no motor assist.
- Enter the "Settings" menu by pressing the [>] and [<] keys and confirm your selection with the pound key [<>].
- Use [+] and [-] to select the menu item "My eBike" and confirm your selection with [<>] or [>].
- Select the menu item "eShift" and confirm your selection.
- Select the menu item "Calibration" and confirm your selection.
-
Pedal the e-bike lightly through the entire calibration process (preferably on a stand with the rear wheel off the ground), while the system shifts from full underdrive to full overdrive multiple times and completes the calibration process.
- This process can take ~25 seconds.
- After completion of the calibration process, the system returns to the ride mode automatically.
Calibration done
If you followed all the steps the e-bike is ready to go. If you have any questions, please contact our Support team.