Bosch Intuvia:
When
• After enviolo AUTOMATiQ assembly;
• When system functions are not appropriate.
How to - for Intuvia
• Turn on the Bosch Intuvia system. Select no motor assist
• Activate the "configuration mode" through simultaneous push and hold of [RESET] and [i] buttons (A).
• Push the [i] button, until you can see "gear calibration" on the screen.
• Lift up the rear wheel and pedal fast and easy.
• While pedaling, press the "Light" button (B) to start calibration
• Continue to pedal for ~20 seconds while the system shifts from full overdrive to full underdrive several times to complete the calibration process.
• After completion of the calibration process, the system returns to the ride mode automatically.
Bosch Nyon
When
• After enviolo AUTOMATiQ assembly;
• After firmware update;
• When system functions are not appropriate.
How to - for Nyon
• Turn on the Bosch Nyon system. Select no motor assist.
• Enter the menu by moving the joystick to the left.
• Select "Settings" and confirm by pressing the joystick.
• Select "My eBike" and confirm by pressing the joystick.
• Select "eShift (NuVinci)" and confirm by pressing the joystick.
• Select "Gear calibration" and confirm by pressing the joystick.
• Lift up the rear wheel and pedal fast and easy.
• While pedaling, select "Continue" by pressing the joystick to start the calibration.
• Continue to pedal for ~20 seconds while the system shifts from full overdrive to full underdrive several times to complete the calibration process and the screen indicates "Gear calibration successful".
• After completion of the calibration process exit the menu.
Bosch Kiox:
When
• After enviolo AUTOMATiQ assembly;
• After firmware update;
• When system functions are not appropriate.
How to - for Kiox:
• Turn on the Bosch Kiox system. Select no motor assist.
• Enter the "Settings" menu by pressing the [>] and [<] keys and confirm your selection with the pound key [<>].
• Use [+] and [-] to select the menu item "My eBike" and confirm your selection with [<>] or [>].
• Select the menu item "eShift" and confirm your selection.
• Select the menu item "Calibration" and confirm your selection.
• Continue to pedal for ~20 seconds while the system shifts from full overdrive to full underdrive several times to complete the calibration process and the screen indicates "Calibration successful".
After completion of the calibration process, the system returns to the ride mode automatically.
Flyer FIT
When
• After enviolo AUTOMATiQ assembly;
• After firmware update;
• When system functions are not appropriate.
How
• Turn on the Flyer system.
• Enter the setup menu using the joystick.
• Select "Calibration" and confirm by pressing the joystick.
• Select "Calibrate NuVinci" and confirm by pressing the joystick.
• Lift up the rear wheel and pedal fast and easy.
• Start calibration by pressing the joystick again.
• Continue to pedal for ~20 seconds while the system shifts from full overdrive to full underdrive several times to complete the calibration process and the screen indicates "Calibration succeeded".