Calibration
On the first set up or after system maintenance or incorrect functionality the system has to be
calibrated.


[C] ENVIOLO CO CONTROLLER
1. Turn system power on. Select no motor assist.
2. Pedal the bicycle lightly through the entire calibration process (preferable on a stand with the rear wheel off the ground).
3. On the enviolo CO controller (1), press and hold the center button for 3 seconds until the rear hub
begins shifting (5-7 seconds) and then release the button.
4. Continue to pedal lightly through the entire calibration procedure, while the system shifts from “low” to “high” ratio multiple times and completes the calibration.
5. Calibration shall not take longer than 12 seconds.

mceclip0.png
[D] ENVIOLO CA CONTROLLER
1. Turn system power on. Select no motor assist.
2. On the enviolo CA controller (1), press and hold up and down button simultanously for 3 seconds until the rear hub begins shifting (5-7 seconds) and then release the button. While the calibration is active, the LED will flash white.
3. Pedal the bicycle lightly through the entire calibration procedure (preferable on a stand with the rear wheel off the ground), while the system shifts from “low” to “high” ratio multiple times and completes the calibration.
4. Once calibration is successful the CA controller lights continously blue for 5 seconds. In case the calibration is unsuccessful the CA controller lights continously red for 5 seconds. Please retry the calibration.
5. Calibration shall not take longer than 12 seconds.

mceclip1.png