This article will explain how to calibrate the AUTOMATiQ, using the integrated FIT System.
Calibration needs to be done after one of the following:
- After the initial assembly of the e-bike.
- When the AUTOMATiQ hub interface was removed from the hub for maintenance reasons.
- When the system does not work properly.
Video instructions
Step-by-step instructions
Tools
- A bicycle with a FIT integrated system.
Calibration instructions
- Turn on the e-bike with the FIT system.
- Enter the setup menu using the joystick.
- Select "Calibration" and confirm by pressing the joystick.
- Select "Calibrate enviolo" and confirm by pressing the joystick.
- Lift up the rear wheel and pedal fast and easy.
- Start calibration by pressing the joystick again.
-
Pedal the e-bike lightly through the entire calibration process (preferably on a stand with the rear wheel off the ground), while the system shifts from full underdrive to full overdrive multiple times and completes the calibration process.
- This process will take ~25 seconds.
Calibration done
If you followed all the steps the e-bike is ready to go.