This guide will walk you through how to manually calibrate the Enviolo AutomatiQ using a CliQ controller, and when the automatic interface has older firmware (R47 and V09, and older).
When to conduct a calibration
Auto calibration
Auto calibration is the best way to calibrate the Enviolo Automatic – available since firmware version R48 and V10. To update your firmware, see: How to update the Enviolo Automatic with the latest firmware version
Auto calibration keeps the system optimized
If your system is up to date – latest app and firmware – the Enviolo Automatic will passively calibrate while riding. It is the best way to keep your system optimised.
Step-by-step instructions
There are 3 different CliQ controllers. Follow the instructions for your model:
A - CliQ Pro
Tools
- A bicycle with a CLiQ Pro already assembled and paired.
Calibration instructions
- Turn the system power on.
- Select “no motor assist”.
- On the controller, press and hold the MODE (1) and DOWN (3) buttons for 3 seconds until the rear hub begins shifting, and then release the button.
- Pedal the bicycle lightly through the entire calibration procedure (preferably on a stand with the rear wheel off the ground), while the system shifts from “low” to “high” ratio multiple times and completes the calibration.
-
Once calibration is successful the controller lights continuously green for 5 seconds.
- In case the calibration is unsuccessful, the controller lights continuously red for 10 seconds. If so, please retry the calibration.
- Calibration shall not take longer than 20 seconds.
B - CliQ Plus
Tools
- A bicycle with a CLiQ Plus already assembled and paired.
Calibration instructions
- Turn the system power on.
- Select “no motor assist”.
- On the enviolo CA controller (1), press and hold the up and down button simultaneously for 3 seconds until the rear hub begins shifting, and then release the button. While the calibration is active, the LED will flash white.
- Pedal the bicycle lightly through the entire calibration procedure (preferably on a stand with the rear wheel off the ground), while the system shifts from “low” to “high” ratio multiple times and completes the calibration.
-
Once calibration is successful the CA controller lights continuously blue for 5 seconds.
- In case the calibration is unsuccessful the CA controller lights continuously red for 5 seconds. If so, please retry the calibration.
- Calibration shall not take longer than 20 seconds.
C - CliQ Pure
Tools
- A bicycle with a CLiQ Pure already assembled and paired.
Calibration instructions
- Turn the system power on.
- Select “no motor assist”.
- Pedal the bicycle lightly through the entire calibration process (preferably on a stand with the rear wheel off the ground).
- On the controller (1), press and hold the center button for 3 seconds until the rear hub begins shifting, and then release the button.
-
Continue to pedal lightly through the entire calibration procedure, while the system shifts from “low” to “high” ratio multiple times and completes the calibration.
- Calibration shall not take longer than 20 seconds.
Other calibration options
Manual calibration
Manual calibration of the Enviolo Automatic is only required when using older firmware versions (pre-firmware R48 and V10) and after one of the following:
- After the initial assembly of the e-bike.
- When the automatic hub interface was removed for maintenance reasons.
- When the system does not work properly.
Manual calibration guides
| Via Enviolo | Via the eBike system |
|---|---|